User's Manual Part 1
AdvancedRFTechnologies,Inc. 29
3.1.2.1 LEDs
RFUhasLEDsonthefrontpanelasshowninFigure3‐10.
Figure3‐10 RFULED
Table3‐2 RFULEDSpecifications
ADXDAS‐Module Specifications
Power SolidGreen ModulepowerisON.
OFF Modulepower is OFF.
SoftFail SolidYellow SoftFailalarmexists intheRFU.
SolidGreen NoSoftFailalarms arepresent intheRFU.
HardFail SolidRed HardFailalarmexists intheRFU.
SolidGreen NoHardFailalarmsarepresentintheRFU.
DLSIGLOW SolidYellow WhenDLinputsignallevelislowerthanthedefinedthreshold
level.(defaultthresholdvalue:‐5dBm)
SolidGreen WhenDLinputsignallevelisupperthanthedefinedthreshold
level.
3.1.2.2 RFPorts
3.1.2.2.1 DLIN/ULOUT&DPXports
DLIN/ULOUT&DPXPorts(refertoFigure3‐7)arelocatedatthebackofRFUandcanbeconnecteddirectlyto
theBTS.TheRFUcansupportincomingsignalstrengthfrom0to25dBm(incaseofBT
andVU,‐15~37dBm).
BTRFUdoesnothaveDLINportbecauseofTDD(Timedivisionduplex)system.
VURFUdoesnothaveDPXportbecausethereisexternallyoptional Duplexercustomizedbyuserrequirement
forVHF/UHFsystem.
3.1.2.2.2 DLOUT/ULIN
DL OUT/UL IN Ports (refer to Figure 3‐7) are
located at the front of the RFU and connect directly to the HE
ChannelCombiner(ADX‐H‐CHC).
3.1.2.3 CommunicationPort
TheADX‐H‐NMSmonitorsandcontrolstheRFUviathisport.DCPowerisalsoprovidedtotheRFUviathisport.
Figure3‐11 CommunicationPort(RFU)
3.1.3 ChannelCombiner(ADX‐H‐CHC)