CARPET EXTRACTOR Operating Instructions (GB/USA) Manuel d’utilisation (FRE) Bedienungsanleitung (GER) MODEL: ADM8IA - 10080010 ADM8IB - 10080020 ADM8IE - 10080030 ADM8IS - 10080040 COUNTRY AUSTRALIA BRITIAN EUROPE SWITZERLAND IPX4 Read these instructions before operating the machine Lire ce manuel avant d’utiliser la machine Bitte lesen Sie diese Anleitungen, bevor Sie die Maschine in Gebrauch nehmen AJ 86038270 10/12/07 PRV NO.
TABLE OF CONTENTS MODEL DATE OF PURCHASE SERIAL NUMBER SALES REPRESENTATIVE # DEALER NAME Data Log/Table of Contents.............. 1 Maintenance ..................................... 15-17 Safety Instructions ............................ 2 Technical Specifications ................... 18 Controls ............................................ 3-5 Parts Lists......................................... 19-34 Operations ........................................ 6-11 Spare Parts/Notes ...........................
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. ! WARNING: To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Use only indoors.
CONTROLS/COMPONENT LOCATIONS 8 9 5 4 6 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets. Intermittent position (up) requires operator to depress 1 of 3 trigger switches to dispense solution. Center position is off. 5. Brush Motor Switch. Turns on brush motor. 6. Vacuum Motor Switch.
CONTROLS/COMPONENT LOCATIONS 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage position to various carpet heights. 4. Recovery Tank. Used to collect dirty cleaning solution. 5. Solution Tank. Used to hold cleaning solution. 6. Recovery Tank Dome. 7. Vacuum Shoe. 8. Brush Housing. 9.
CONTROLS/COMPONENT LOCATIONS 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle.
FILLING OPERATIONS STEP 1 RECOVERY TANK Remove recovery tank SOLUTION TANK STEP 2 or Add water 8 gal. (30.3 ltr.) 140°F (60°C) FILL LINE STEP 3 FILLING THE ADMIRAL 8 – 16oz. (237ml – 473ml) NOTE: Use clean bucket of water to fill solution tank Add cleaning chemical Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank. Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before replacing recovery tank.
OPERATIONS STEP 1 STEP 2 STEP 3 1/8in (3mm) CORRECT Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions page 6). Plug cord into grounded outlet. Note: Be sure dome is seated on recovery tank, and float shut-off is installed correctly. Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to motor or carpet.
OPERATIONS Adjust handle to comfortable operating position. Tip machine back by main handle to move to starting point. STEP Lower machine to floor. STEP Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray. The intermittent setting requires the operator to hold any one of the three trigger switches in the “on” position with the fingers, and is typically used in small areas where short cleaning passes are made.
CLEANING PROCEDURE STEP 1 STEP 2 1ft. (30cm) OFF STEP 1in. (25mm) 3 SOLUTION INTAKE COVER VACUUM INTAKE COVER 9 STEP 4 Start at wall closest to power outlet. Pull straight back without pushing down on handle. Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass.
CLEANING PROCEDURE Use right side of machine for cleaning against walls. STEP After cleaning, turn off all controls, return brush to storage position and carefully unplug machine. STEP 5 6 OFF OFF To speed drying, use a Windblower™ fan. STEP Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use.
ACCESSORY TOOL USAGE STEP 1 Use only one of the following acceptable accessory tools. 86000020 – PRV NO. HT 86000000 – PRV NO. DDH 86041150 – PRV NO. DH 86031540 – PRV NO. 39504 86000610 – PRV NO. 89227 86000600 – PRV NO. 89226 Pull back collar and insert over machine mounted fitting, then release collar to lock into place. STEP 2 STEP 3 SOLUTION BRUSH INT VACUUM ON Lift door on front of vacuum shoe and insert 1 ½ inch hose cuff into hole.
TROUBLESHOOTING CHART PROBLEM CAUSE SOLUTION 1. Is the cord plugged in. 1. Plug in cord. 2. Circuit breaker tripped in building. 2. Reset breaker 3. Faulty switch. 3. Call for service. 4. Faulty power cord or pigtail. 4. Call for service. Vacuum Motor Will Not 1.Vacuum circuit breaker tripped. 1.Reset breaker Run 2.Faulty main vacuum switch. 2.Call for service. 3.Loose wiring. 3.Call for service. 4.Faulty vac motor. 4.Call for service. Vacuum Motor Runs But 1.Debris lodged in vac shoe.
THIS PAGE LEFT INTENTIONALLY BLANK 13 ADMIRAL 86038270 05/22/07
WIRING DIAGRAM 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430 PRV NO. 88323 FILTER 86003650 PRV NO. 34362 86268370 PRV NO. 88276 86268430 PRV NO. 88323 86238830 PRV NO. 41355 86268900 PRV NO. 88655 86238840 PRV NO. 41356 86266720 PRV NO. 880043 86268430 - PRV NO. 88323 86268420 PRV NO. 88317 86268750 PRV NO. 88567 86238820 PRV NO. 41351 86001240 PRV NO.
MAINTENANCE PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry. NOTE: Always store machine with brush in “Store” position. NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern.
MAINTENANCE ! WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Locate the vacuum motor wires and disconnect at the connector. Close the solution tank. 5. Remove the (6) screws holding the vacuum motor cover (p/n 86003080 – PRV NO.
MAINTENANCE SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses from fittings in pump. 5. Remove the (2) screws that fasten the pump to the frame. 6. Reverse process to install pump. Pump Replacement Parts for Shurflo 100 psi (86026400 – PRV NO. 65254) PumpHead 86251040 PRV NO.
TECHNICAL SPECIFICATIONS POWER TYPE GENERAL DIMENSIONS/WEIGHT ELECTRICAL: 230-240 V, 7 A, 50 HZ Vacuum shoe: 17” (43.18 cm) cast aluminum with spring loaded down pressure ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift – 117” (297cm) WHEELS: (2) 10” dia. (25 cm) wheels by 2” WEIGHT: 92 lbs. (42 kg) BRUSH: (1) 15” (38.1 cm.) LENGTH: 35” (89 cm) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass HEIGHT: 42” (107 cm) SOLUTION CAPACITY: 8 gallons (30.