1.2.10. Power Consumption
Capacity Description Min Max Unit
16 GB Operating voltage for 5V (+/- 5%) 4.75 5.25 V
32 GB Operating voltage for 5V (+/- 5%) 4.75 5.25 V
Table 7: Operating Voltage
Capacity Mode Type Unit
Active (average) 0.95 W
16 GB
Idle (average) 0.55 W
Active (average) 0.95 W
32 GB
Idle (average) 0.55 W
Table 8: Typical Power Consumption
Note: Active power is measured using IOMETER Power Consumption using Data Logger _No
DIPM
1.2.11. Temperature
Environment Mode Min Max Units
Operating 0 70 °C
Ambient
Temperature
Non-operating -40 85 °C
Operating 5 95 %
Humidity
Non-operating 5 95 %
Table 9: Temperature Relative Specifications
Note: Measured without condensation
1.2.12. Reliability
Parameter Value
Mean Time between Failure (MTBF) > 1,500,000 hours
Power on/off cycles 50,000 cycles
Minimum useful life 3 years
Table 10: Reliability specifications