User`s manual

6 Introduction
PCI-9524 ADLINK Technology Inc.
User’s Manual Copyright 2008
Table 1-5: Settling Error: (Typical, 25°C)
X Time-base source: Internal 40 MHz
X Trigger mode: post-trigger
X Offset error:
Z Before calibration: ±0.5mV typical
Z After calibration: ±0.001mV typical (auto-zero disabled),
< ±0.001mV typical (auto-zero enabled)
X Transfer Linearity:
Z Better than: ±0.0035% over full-scale input range
X Gain error:
Z Before calibration: ±1% typical
Z After calibration: ±0.5% typical
Analog Input (AI) for General Purpose
X Number of channels: (programmable)
Z 4 differential input (DI)
X A/D converter:
Z ADS1255
X Maximum sampling rate:
Z 30,000 samples/s (single channel)
Z 1.638 samples/s (multiplexed/scanning)
X Resolution:
Z 24-bit
X Input coupling: DC
Input Range Condition Settling Error
±200mV Scanning 200mV step max 0.01%