User`s guide

Signal Connection 27
3.5 Origin signal ORG
The origin signals (ORG1~ORG6) are used as input signals for origin of the
mechanism. The following table is the pin assignment for ORG.
CN1 Pin No.
Signal Name Description Alternative Name
6 COM+ Ext +24V COM+
7 COM+ Ext +24V COM+
8 COM+ Ext +24V COM+
9 ORG1 Origin signal, DI 1
59 ORG2 Origin signal, DI 2
13 ORG3 Origin signal, ƒ DI 3
63 ORG4 Origin signal, DI 4
17 ORG5 Origin signal, DI 5
63 ORG6 Origin signal, DI 6
55 COM- Ext Common Ground COM-
56 COM- Ext Common Ground COM-
Notice that the alternative name means that if users don’t use motion
functions at one or more axes, the digital input will be treated as general
purpose input channel.
The input circuits of the ORG signals are shown as following. Usually, a limit
switch is used to indicate the origin of one axis. The specifications of the limit
switches should with contact capacity of +24V, 6mA minimum. An internal
filter circuit is used to filter out the high frequency spike, which may cause
wrong operation.
Figure 3.4.1 Connection of ORG
When the motion controller is operated at the home return mode, the ORG
signal is used to stop the control output signals (OUT and DIR) a utomatically.