User`s manual

Application Hints 45
PCIS-DASK
Analog Input
Non-Trigger Non-double-buffered Asynchronous
Continuous Analog Input
This section describes the function flow typical of non-trigger, non-
double-buffered asynchronous analog input operation. While per-
forming continuous AI operation, the AI configuration function has
to be called at the beginning of your application. In addition, for
asynchronous AI, the SyncMode argument in continuous AI func-
tions has to be set to ASYNCH_OP.
NO
AI_ContReadChannel/
AI_ContReadChannelToFile
AI_ContScanChannels/
AI_ContScanChannelsToFile
Sample multiple
continuous channels?
AI_XXXX_Config
(XXXX = card type)
NOYES
Operation complete?
AI_AsyncClear
YES
With SyncMode
= SYNCH_OP
AI_AsyncCheck
With SyncMode
= SYNCH_OP