User`s manual

2 • Introduction
1.2 Applications
Industrial ON/OFF control
External high power relay driving and signal switching
Laboratory automation
Industrial automation
Switch contact status sensing
Limit switch monitoring
Cooperating with other modules such as A/D and D/A peripherals to
implement a data acquisition and control system
1.3 Specifications
Relay Output
Number of channels: 24
Relay type: DPDT (2 Form C), non-latching
Switching capacity:
Max. switching current: 2A
Max. switching voltage: 220V
DC
, 125V
AC
Max. switching power: 50VA, 60W
Max. carrying current: 2A
Failure rate: 10µA
Contact resistance: 100m max.
Relay set/reset time
Operate time: 4ms max.
Release time: 4ms max.
Bounce time: 1ms max.
Expected life:
Mechanical life: 10
8
operations min.
Electrical life: 5x10
5
operations min. (1A @ 30V
AC
, resistive load)
Data transfer: Programmed I/O
Auxiliary Digital I/O
Numbers of channel: 3 inputs/outputs
Compatibility: 3.3 V/TTL (5V tolerant)
Data transfers: programmed I/O
Handshaking Signals
Programmable polarity
Logic level: 3.3 V/TTL (5V tolerant)
Trigger In source: TRG_IN, PXI trigger bus, PXI star trigger in
Scanner Advanced destination: S_ADV, PXI trigger bus, PXI star
trigger out