User`s guide
Installation • 15
2.10 Jumper Setting
The J1~J8 is used to set the signal type of the pulse output signals (DIR
and OUT). The output signal type could be differential line driver output or
open collector output. Please refer to section 3.1 for details of the jumper
setting. The default setting is the differential line driver mode.
Line Driver
Open Collector
2.11 Switch Setting
The switch S1 is used to set the EL limit switch’s type. The default setting
of EL switch type is “normal open” type limit switch (or “A” contact type).
The switch on is to use the “normal closed” type lim it switch (or “B” contact
type). The default setting is set as normal open type.
Placement of S1 Switch on Board
1
2
3
J1 J2 J3 J4 J5 J6 J7 J8
Axis
1
2
3
4
ON
OFF
S1
Select ‘a’ Contact EL Switch (Normal Open)
Select ‘b’ Contact EL Switch (Normal Close)