User`s guide
Operation Theory
43
(UC _Counter=8, IC_Counter=1)
8 update counts, 1 iteration
DAWR
WFG_in_progress
O
p
eration start
Trigger
Output Waveform
Delay until
DLY1_counter
reaches 0
Figure 24: Delay trigger waveform generation
(Assuming the data in the data buffer are 2V, 4V, 6V, 3V, 0V, -4V, -2V, 4V)
Post-Trigger or Delay-Trigger with Re-trigger
Use post-trigger or delay-trigger with re-trigger function when you want to
generate waveform after more than one trigger events. The re-trigger
function can be enabled or disabled by software setting. In figure 25, each
trigger signal will generate 2 single waveforms (since IC_Counter = 2), and
you can set
Retrig_no
to specify the number of the accepted re-trigger
signals. Note that a trigger would be ignored if it occurs during waveform
genera-
tion.
(UC _Counter=4, IC_Counter=2, retrig_no=3)
4 update counts, 2 iterations
Ignored
DAWR
WFG_in_progress
Operation start
Trigger
Output Waveform
0
2
4
a single waveform
Figure 25: Re-triggered waveform generation with Post-trigger and
DLY2_Counter = 0
(Assuming the data in the data buffer are 2V, 4V, 2V, 0V)