User`s guide
Operation Theory • 61
Summary of the auxiliary function input signals and the corresponding
functionalities
Category Timing signal
Functionality Constraints
EXTTIMEBASE
Replace the
internal
TIMEBASE
1. TTL-compatible
2. 1MHz to 40MHz
3. Affects on both A/D and
D/A operations
EXTDTRIG
External digital
trigger input for
A/D operation
1. TTL-compatible
2. Minimum pulse width =
20ns
3. Rising edge or falling edge
Dedicated
input
EXTWFTRG
External digital
trigger input for
D/A operation
1. TTL-compatible
2. Minimum pulse width =
20ns
3. Rising edge or falling edge
Replace the
internal
ADCONV
1. TTL-compatible
2. Minimum pulse width =
20ns
3. Rising–edge sensitive only
AFI[0]
(Dual functions)
Replace the
internal
SCAN_START
1. TTL-compatible
2. Minimum Pulse
width > 2/TIMEBASE
Multi-
function
input
AFI[1]
Replace the
internal DAWR
1. TTL-compatible
2. Minimum pulse width =
20ns
3. Rising–edge sensitive only
Table 15: Auxiliary function input signals and the corresponding
functionalities