User`s guide
2 • Introduction
• Programmable gain
P DAQ/PXI-2204: x1, x2, x4, x5, x8, x10, x20, x40, x50, x200.
P DAQ/PXI-2205/2206: x1, x2, x4, x8.
• A/D FIFO size: 1024 samples
• Versatile trigger sources: software trigger, external digital trigger,
analog trigger and trigger from System Synchronization Interface (SSI)
• A/D Data transfer: software polling & bus -mastering DMA with Scat-
ter/Gather functionality
• Four A/D trigger modes: post-trigger, delay-trigger, pre-trigger and
middle-trigger
• 2 channel D/A outputs with waveform generation capability
• 1024 word length output data FIFO for D/A channels
• D/A Data transfer: software update and bus -mastering DMA with
Scatter/Gather functionality
• System Synchronization Interface (SSI)
• A/D and D/A fully auto-calibration
• Completely jumper-less and software configurable