Specifications

Command Set 3-29
@Example
User command: $01B0<CR>
Response: !011<CR>
! Command is valid.
01 Address ID.
1 Open thermocouple of channel 0
User command: $01BA<CR>
Response: !1FE<CR>
! Command is valid.
01 Address ID.
FE Open thermocouple of channel 1~7
Close thermocouple of channel 0
Notice: The open detection function is immediate scanning by hardware
every 500ms. Disable channel and input out of high temperature
range will be recognized as open T/C.