Specifications
Command Set 3-41
3. 34. Set Alarm Limit Value of Counter 1
@Description
Set the alarm limit value of counter 1.
@Syntax
@(Addr)SA(ArmData)<CR>
@
Command leading code.
(Addr) Address ID (2-character)
SA
Set alarm limit value command code.
(ArmData)
The alarm limit value which consists of 8
hexadecimal digits.
@Response
!(Addr)<CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr)
Address ID.
@Example
User command: @30SA0002FFFF<CR>
Response: !30<CR>
Item Meaning Description
@ (Leading Code) Command leading code.
30 (Addr) Address ID is 30H.
SA Set alarm limit value of
counter 1.
0002FFFF (ArmData) 196607(0x0002FFFF)