Specifications

3-30 Command Set
3. 23. Set Minimum Input Signal Width at High Level
@Description
Set the minimum input signal width at high level, for signal level
high less then this value will be filtered out as noise.
@Syntax
$(Addr)0H(MinFData)<CR>
$
Command leading code.
(Addr) Address ID (2-character)
0H
Set minimum input signal width at high level
command code.
(MinFData)
The minimum width data at high level. The unit
is µs and its resolution is 1 µs. This value range
from 4 µs to 1020 µs, which is a 4-digit integer.
(4-character)
@Response
!(Addr)<CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr)
Address ID.
@Example
User command: $300H0100<CR>
Response: !30<CR>
Item Meaning Description
$ (Leading Code) Command leading code.
30 (Addr) Address ID is 30H.
0H Set minimum input signal
width.
0100 (MinFData)
100 µs