Specifications

3-20 Command Set
@Example
User command: #30H31<CR> (for ND-6056)
Response: ><CR>
30
Address ID
H
Set output to high byte
3
Channel number is 3, that is channel 11
1
Set corresponding channel to ON
User command: #2FA20<CR>
Response: ><CR>
2F
Address ID
A
Set output to port A
2
Channel number is 2
0
Set corresponding channel to OFF