Specifications

3-18 Command Set
@Example
User command: #30H03<CR> (for ND-6056)
Response: ><CR>
30
Address ID
0H
Set output to high byte
03
03 (00000011), Channel 8 and 9 are set ON other
channels are set to OFF
User command: #2F0A10<CR>
Response: ><CR>
2F
Address ID
0A
Set output to port A
10
Set channel 4 of port A ON