Specifications
Data Format and Input Range 4-3
2. digits
3. decimal point
• Data is sign (+ or - ) followed with 5-digits and a decimal point.
• It does not exceed 7-characters.
• Maximum resolution is 0.01%, the decimal point is fixed.
• Data is the ratio of input signal to the value of full scale range.
Example 1 :
• Input Range is ±5 V
• Input is +1 Volts
% of FSR : +020.00<CR>
(+(20/100) x 5 V) = +1 V
Example 2 :
• Input Range is ±10 V
• Input is +4 Volts
% of FSR : +040.00<CR>
(+(40/100) x 10 V) = +4 V
Example 3 :
• Input Range is Type K thermocouple (range 0°C to 1000°C)
• Input is 406.5°C
% of FSR : +040.65<CR>
(+(40.65/100) x 1000°C ) = 406.5°C