User`s guide
42 • Operation Theory
Figure 12. Post Trigger timing
Under pre-trigger or post-trigger control schemes, the TRGEVENT flag signal
(Base + 0Ch) can come in handy. When the pre-trigger or post-trigger signal is
inserted, the TRGEVENT will be set to 1. After an acquisition or before the
next trigger signal is inserted, the trigger event flag (TRGEVENT, Base + 0Ah)
most be cleared by the user in order to set the correct flag status for the next
incoming trigger event.
Note that either the pre-trigger mode or post-trigger mode can be enabled at
any one time and not both. The post-trigger mode is only available with
hardware revision B2.
Time
POTRG Signal
1.
Disable the A/D trigger source and set the
Post-trigger ON.
2. Set up A/D acquire mode.
3.
Reset FIFO.
4. Enable A/D trigger
source.
5. Post
-
trigger signal assert.
6. Disable A/D trigger source
to stop acquiring data.
A/D conversion
signal