User`s guide
12 • Installation
2.3 PCI-9111 PCB Layout
Figure 1. PCB Layout of the PCI-9111
2.4 Jumper Descriptions
There is only one configurable jumper (JP1) available on the PCI-9111 card
and is used to s et the range for the analog output channel. The analog output
range can be uni-polar (0~10V) or bi-polar (-10V~+10V). The default setting is
bi-polar. See table below for setting possibilities.
Analog output range is
-10V~+10V
Analog output range is
0V~ +10V
UI
BI
JP1
UI
BI
JP1
Figure 2. Analog output range setting