User`s guide

6 Introduction
Programmable Counter
Device: 8254
A/D pacer: 32-bit timer
(Two 16-bit counters cascaded together) with a 2MHz time base
Pacer Output: 0.00046 Hz ~ 100 KHz
Pre-trigger Counter:
One 16-bit counter for counting AD Conversion Pulse
General Specifications
Connector: 37-pin D-type connector
Operating Temperature: 0°C ~ 60°C
Storage Temperature: -20°C ~ 80°C
Humidity: 5 ~ 95%, non-condensing
Power Consumption: +5 V @ 570 mA typical
Dimension: Compact size only 175mm x 105mm