User`s guide

2
ACLD-9185
l Screw terminal for easily wiring
1.1.2 Specifications
Output Channels
16
Relay Type 16 SPDT ( Form C )
Contact rating 120V AC/DC, 1A
Breakdown Voltage 1000V AC/DC min..
Release time 5 msec max.
Operate time 5 msec max..
Relay ON time 3 msec typical
Relay OFF time 3 msec typical
Total switching time 10 msec typical
Insulation Resistance 100 mega Ohms min.
Life Expectancy > 5 million operations at full load
Power Consumption +12V , 33mA for each relay, total 0.53A if
all relay are energized +5V, less than 0.2A
Power supply +12V from the PC-Bus
Size
203 mm X 132mm
Connectors 20-pin flat cable
1.2 Installation
To install and operate the ACLD-9185, you can follow the following steps:
Ø Check what you have in the box
Ø Check the PCB
Ø Set jumper (set power source)
Ø Make connection to add-on cards
Ø Program the add-on cards
1.2.1 What you have
In addition to this User's Manual, the package includes the following items:
l ACLD-9185 Relay Output Board
l Cable
l Nylon standoffs for table-top or panel mounting
If any of these items was missed or damaged, contact the dealer whom
you purchased. Save the shipping materials and carton in case you want
to ship or store the product in the future.