User`s manual
4Introduction
Analog Input (AI)
X Channels:
Z DAQ-/PXI-2502: 4 single-ended
Z DAQ-/PXI-2501: 8 single-ended
X AD converter: LTC1416
X Max sampling rate: 400 KS/s
X Resolution: 14-bit
X FIFO buffer size: 2K samples
X Input range
Z Bipolar: ±10 V
Z Unipolar: 0 V to 10 V
X Over-voltage protection: Continuous, ±35 V maximum
X Input impedance: 1 GΩ / 6 pF
X Trigger modes: Pre-trigger, post-trigger, middle-trigger, and
delay trigger
X Data transfers: Programmed I/O and bus-mastering DMA
with scatter/gather
X Input coupling: DC
X Offset error:
Z Before calibration: ±40 mV max
Z After calibration: ±1 mV max
X Gain error:
Z Before calibration: ±0.4% of max output
Z After calibration: ±1 mV of max output