User`s guide
2 • Introduction
1.2 Applications
l Measurement of transducer and sensor data
l Multiple channel measurement
l Waveform acquisition and measurement
l Process monitor
l Vibration and transient analysis
l Signal isolation
1.3 Specifications
The ACL-8113A provides the following specifications:
Analog Input (A/D)
l Input Channel: 32 Isolated channels
l Resolution: 12-bit
l Input Range:
10V Range:
Bi-polar: ± 5V, ±2.5V, ±1.25V, ±0.625V, ±0.3125V
Uni-polar: 0~10V, 0~5V, 0~2.5V, 0~1.25V, 0~0.625V
20V Range:
Bi-ploar: ± 10V, ±5V, ±2.5V, ±1.25V, ±0.625V
Uni-polar: 0~10V, 0~5V, 0~2.5V, 0~1.25V
Over-voltage Protection: Continuous ± 35V maximum
l Converter Type: Successive approximation
l Converter: B.B. AD774 or equivalent
l Conversion Speed: 50 KHz maximum
l Accuracy: 0.015% of reading ± 1 LSB
l None-linearity: ± 1 bit maximum
l AD conversion trigger Mode: Software Trigger
l Data Transfer: Program Control
l Input Impedance: > 10MΩ
l Temperature coefficient: 5 ppm typical, 15 ppm maximum