User`s manual
Table Of Contents
- Table of Contents
- List of Tables
- List of Figures
- 1 Introduction
- 2 Installation
- 3 Signal Connections
- 4 Operation Theory
- 5 Calibration
- Appendix
- Warranty Policy

Operation Theory 35
will be a 1/8-cycle sine wave for every waveform period. In
other words, a complete sine wave will be generated for every
8-iterations. If value specified in UC_counter is larger than the
sample size of waveform LUT, say, 32; the generated wave-
form will be a 2-cycle sine wave for every waveform period.
In conjunction with different trigger modes and counter setups,
users can manipulate a single waveform to generate different,
more complex wave-forms. For more information, please refer
to Appendix A.
Figure 4-12: Finite iterative waveform generation w/Post-trigger
(Assuming the digital codes in the FIFO are 2V, 4V, 2V, 0V)