User`s manual
Function Library 229
The second is for event_int_status, which can be masked by
_8164_set_int_factor(). See table below:
event_int_status: can be masked by function call
_8164_int_factor()
_8164_link_interrupt: (Windows only.)
Links to the interrupt call back function.
_8164_get_int_type: (DOS only)
Detects the type of INT that occurred.
Bit Description
0Normal Stop
1 Next command Starts
2 Command pre-register 2 is empty
3 (Reserved)
4 Acceleration Start
5 Acceleration End
6 Deceleration Start
7 Deceleration End
8 (Reserved)
9 (Reserved)
10 (Reserved)
11 General Comparator compared
12 Trigger Comparator compared
13 (Reserved)
14 Counter Latched for axes 2 and 3
15 ORG Input and Latched
16 SD on
17 (Reserved)
18 (Reserved)
19 CSTA, Sync. Start on
20-30 (Reserved)
31 Axis Stop Interrupt