User`s manual

66 Power Supply Unit
Input Characteristics
X Input Voltage: Typ. 90 - 264 VAC
X Power Factor Correction: Meets Harmonic Correction
IEC1000-3-2. Power Factor typ. 0.95-0.97
X Input Connector: Positronic 47-pin PCIH47M400A1
X Input Frequency: 47-63Hz
X Inrush Current: Less than 30A @ 230VAC
X Input Current: 2.8A @115VAC / 1.4A @230VAC
X Dielectric Withstand: Meets IEC950 regulations
X EMI: Meets EN55022 / FCC Class A
X Hold-up Time: 5mS after power fail signal
X Remote ON/OFF: Available at [INH#] & [EN#] pins
X Power Fail Signal: Available at [FAL#] pin
X Status LED: <Green> means valid input voltage; <Amber>
means a critical fault.
X Thermal Protection (OTP): Installed NTC and thermostat for
thermal sensor at [DEG#] pin
X Power OK: Installed at all outputs
X Leakage Current: Typ. 0.5mA
Output Characteristics
Output Voltage
(see below for properties)
Output Current (A)
MIN. MAX. TYP. PEAK.
5V
MAIN +VO1
(1, 2, 3, 4, 6)
2.0 33.0 25.0 –
3.3V
AUX. +VO2
(1, 2, 3, 4, 6, 7)
0 33.0 18.0 –
12V
AUX. +VO3
(1, 2, 3, 4, 6, 7)
05.55.56.0
-12V
AUX. –VO4
(1, 5, 6, 8, 9)
010.51.5