User`s guide
Appendix C • 73
• CLEAR SEL – Clears all records from the SEL and provides status of
the operation.
• GET SEL TIME – Returns the time from the SEL device.
• SET SEL TIME - Initializes the time in the SEL device.
C.1.4.7 Chassis Commands
• GET POH COUNTER – The firmware returns system up time since last
power cycle.
C.1.4.8 BMC Watchdog Timer Commands
The following commands are supported for the firmware.
• RESET WATCHDOG TIMER – Used to start and restart the watchdog
timer.
• SET WATCHDOG TIMER – Used to initialize and configure the
watchdog timer. Also used to stop the watchdog timer.
• GET WATCHDOG TIMER – Retrieves the current settings and present
countdown of the watchdog timer.
C.1.4.9 FRU Inventory Commands
This section lists the commands used to support the Field Replaceable
Unit (FRU) repository functions. The Zircon allows the OEM to configure the
FRU devices by editing the Configuration File and SDRR file.
• GET FRU INVENTORY AREA INFO – Returns overall size of the FRU
Inventory area in this device, in bytes.
• READ FRU INVENTORY DATA – Returns FRU Inventory data specified
by offset, count and FRU Device ID.
• WRITE FRU INVENTORY DATA – Writes FRU Inventory data specified
by offset, count and FRU Device ID.