Technical data
Operating the sewing unit
34
Operating manual 743-221-01 version 01.0 - 09/2013
5.14 Setting the control unit
At this point only the settings needed for sewing will be mentioned.
Additional settings on the technician level are described in the Service
Instructions.
The control unit is operated via the operating panel OP3000, 4.2 Soft-
ware description, p. 16.
After switching on the machine the firmware and software versions will
briefly be displayed. After this start the reference run by pressing the
“OK“ key, p. 17.
After the reference run the main menu is displayed.
5.14.1 Functions in the main menu
Fig. 18: Main menu
Main menu - Top line
• Select the desired parameter with the arrow keys (◄,►).
The activated parameter is highlighted.
• Enter the desired value by using the arrow keys (▼,▲).
The value is directly applied and memorized for the particular program.
Program selection
Program number entry
Range of values: 1 - 20
Seam length
Seam length entry in mm
Range of values: 19 - 150
Important: The seam length can only be entered if the light barrier
(
p. 35) is disabled.
Stitch length
Stitch length entry in mm
Range of values: 0.5 - 3.0
(1) - Program selection
(2) - Seam length
(3) - Stitch length
(4) - hook thread counter
(5) - Seam counter
(6) - Submenu
(7) - Switching additional functions on/off
ཱཱཱིིུུ
ྲྀ