Instruction manual
2.2 Operator Controls at the Controls
The needle- and underthread monitors are activated with the DIP
switch b417 at the controls.
The dials b401 and b402 have no function.
Caution Electric Current !
The switches may only be altered with the main switch turned off.
ATTENTION !
The switches are only verified once after the sewing unit is turned on.
After changing the switch setting turn the main switch off and on again
or operate the " STOP " key.
DIP switch Dials
b417 b401 b402
DIP switch open closed
b417
1 - Reserve - -Reserve -
2 Needle thread monitor active Needle thread monitor not active
3 - Reserve - - Reserve -
4 - Reserve - - Reserve -
5 Underthread monitor not active Underthread monitor active
6 - Reserve - - Reserve -
7 - Reserve - - Reserve -
8 - Reserve - - Reserve -
Dial b401 0...9 = no function
Dial b402 0...9 = no function