Instruction manual

4.12 Checking the Input Elements
Program 62 checks the input elements.
Set the "Program" switch to "62".
Press the "STOP" key. The program is activated.
Press the input element.
The wiring diagram designation and the switching status of the
input element appear in the display (e.g. "+B25").
The display changes when the switching status of any other input
element is changed.
The switching status "+" means:
By contact switch = Open contact
By proximity switch = Metal in front of the switch
By reflecting light barrier = No reflection
Transmitted light barrier = Light beam not interrupted
4.13 Selecting Input Elements
ATTENTION !
All input elements were carefully set at the factory.
The resetting and correction may only be conducted by trained service
personnel.
Program 63 is used for setting the input elements.
Set the " Program " switch to " 63 ".
Press the " STOP " key.
The program is activated.
Set the " Program " switch to the selected input element (see
Table).
Adjust the input element (switching flag, switching cam, etc.) until
the desired switching status appear.
Input Function
Element
b03 Table forward
b04 Sewing enabled
b05 Transport carriage left
b07 Transport carriage right
b12 knee-switch
b14 Needle thread monitor
b15 Form set slewing
b16 Form set control
b45 Light barrier seam end
b46 Remaining thread monitor
18