Technical data
Set-up instructions
102 Operating manual 867 Version 01.0 - 12/2012
7.12.9 Setting machine-specific parameters
With DAC controllers the parameters are automatically set via
transfer of the machine ID.
With Efka controllers the parameter F-290 must be set for each
submodel according to the specifications in Parameter sheet.
The parameter sheet is provided in the controller accessory pack.
1. Set parameter F-290 according to the specifications in
Parameter sheet.
For submodel 867-290342-100 only:
2. Set parameter F-111 to 2500 min
-1
or less.