User manual
ADJ Products, LLC - www.adj.com - UB 6H User Manual Page 13ADJ Products, LLC - www.adj.com - UB 6H User Manual Page 12
Master-Slave Configuration: 
This function will allows you to link units together to run in a Master-
Slave mode. In Master-Slave operation  one  unit  will  act  as  the  con-
trolling  unit  and  the  others  will  react  to  the  controlling  units  built-in 
programs. Any unit can act as a Master or as a Slave however, only 
one unit can be programmed to act as the “Master.” 
Master-Slave Connections and Settings:
1.  Daisy chain your units via the XLR connector on the rear of the 
 unit. Use standard XLR data cables to link your units together.  
    Remember that the Male XLR connector is the input and the  
 Female XLR connector is the ouput. The first unit in the chain 
 (master) will use the female XLR connector only. The last unit in  
 the chain will use the male XLR connector only. 
2. Set the “Master” unit to your desired mode of operation. 
3.   Connect the rst “Slave” unit to the “Master.”
4. On the “Slave” unit set it to the DMX MODE setting. The “Slave” 
    unit will now follow the “Master”.
 UB 6H Master-Slave Configuration 
DMX State:
This mode can be used as a precaution mode, that in case the DMX 
signal is lost, the operating mode chosen in the setup is the running 
mode the xture will go into when the DMX signal is lost. You can also 
set this as the operating mode you would like the unit to return to when 
power is applied.
1. Plug the fixture in and press the MODE button until “d.XXX” is dis-  
 played. “XXX” represents the current displayed DMX address.   
2. Press the SET UP button so that “nodn” is displayed. Use the UP 
 and DOWN buttons to scroll through the DMX states.
 • “bLAC” (Blackout) - If the DMX signal is lost or interrupted, 
 the unit will automatically go into stand by mode.
 • “LASt” (Last State) - If the DMX signal is lost or interrupted,   
 the xture will stay in the last DMX set up. If power is applied and 
 this mode is set, the unit will automatically go into the last DMX set 
 up. 
 • “ProG” (Auto Run) - If the DMX signal is lost or interrupted, 
 the unit will automatically go into Auto Run mode.
3. Use the UP and DOWN buttons to nd your desired DMX state 
 and press SET UP to conrm and exit. 
Dimmer Curve:
This  is  used  to  set  the  dimming  curve  used  with  DMX  mode.  See 
page 21 for the different dimming curves. 
1.  Plug the fixture in and press the MODE button until the current 
    DMX address is displayed.
2.  Press the SET UP button until “dr-X” is displayed. “X” represents 
    the displayed dimmer curve (0-4).
 •   0 - Standard
 •   1 - Stage
 •  2 - TV
 •   3 - Architectural
 •   4 - Theatre
3.  Press the UP or DOWN buttons to scroll through and select your 
    desired dimming curve.
 UB 6H Operating Instructions
Default Running Mode:
This is a default running mode. When this mode is activated all modes 
will return to their default settings and a Auto program will run. 
1.  Plug the fixture in and press the MODE button until “dXX” is dis- 
   played. “XX” represents either “on” or “oFF”.
2.  Press the SET UP button until “dEFA” is displayed. 
3.   Press the UP and DOWN buttons at the same time. 
With  this  feature  you  can  connect  the  xtures  to  one  another 
using the  IEC input  and output  sockets. The  maximum  that  can 
be connected is 16 xtures @ 120V and 29 xtures @ 240V. After 
the  maximum  connected  fixtures  you  will  need  to  use  a  new 
power outlet. 
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES 
TO  THE  UB  6H  AS  THE  POWER  CONSUMPTION  OF  OTHER 
LIGHTING FIXTURES WILL VARY!
 UB 6H Multiple Unit Power Linking
 UB 6H Operating Instructions