User manual

ADJ Products, LLC - www.adj.com - UB 6H User Manual Page 13ADJ Products, LLC - www.adj.com - UB 6H User Manual Page 12
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave mode. In Master-Slave operation one unit will act as the con-
trolling unit and the others will react to the controlling units built-in
programs. Any unit can act as a Master or as a Slave however, only
one unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the
unit. Use standard XLR data cables to link your units together.
Remember that the Male XLR connector is the input and the
Female XLR connector is the ouput. The first unit in the chain
(master) will use the female XLR connector only. The last unit in
the chain will use the male XLR connector only.
2. Set the “Master” unit to your desired mode of operation.
3. Connect the rst “Slave” unit to the “Master.”
4. On the “Slave” unit set it to the DMX MODE setting. The “Slave”
unit will now follow the “Master”.
UB 6H Master-Slave Configuration
DMX State:
This mode can be used as a precaution mode, that in case the DMX
signal is lost, the operating mode chosen in the setup is the running
mode the xture will go into when the DMX signal is lost. You can also
set this as the operating mode you would like the unit to return to when
power is applied.
1. Plug the fixture in and press the MODE button until “d.XXX” is dis-
played. “XXX” represents the current displayed DMX address.
2. Press the SET UP button so that “nodn” is displayed. Use the UP
and DOWN buttons to scroll through the DMX states.
• “bLAC” (Blackout) - If the DMX signal is lost or interrupted,
the unit will automatically go into stand by mode.
• “LASt” (Last State) - If the DMX signal is lost or interrupted,
the xture will stay in the last DMX set up. If power is applied and
this mode is set, the unit will automatically go into the last DMX set
up.
• “ProG” (Auto Run) - If the DMX signal is lost or interrupted,
the unit will automatically go into Auto Run mode.
3. Use the UP and DOWN buttons to nd your desired DMX state
and press SET UP to conrm and exit.
Dimmer Curve:
This is used to set the dimming curve used with DMX mode. See
page 21 for the different dimming curves.
1. Plug the fixture in and press the MODE button until the current
DMX address is displayed.
2. Press the SET UP button until “dr-X” is displayed. “X” represents
the displayed dimmer curve (0-4).
0 - Standard
1 - Stage
2 - TV
3 - Architectural
4 - Theatre
3. Press the UP or DOWN buttons to scroll through and select your
desired dimming curve.
UB 6H Operating Instructions
Default Running Mode:
This is a default running mode. When this mode is activated all modes
will return to their default settings and a Auto program will run.
1. Plug the fixture in and press the MODE button until “dXX” is dis-
played. “XX” represents either “on” or “oFF”.
2. Press the SET UP button until “dEFA” is displayed.
3. Press the UP and DOWN buttons at the same time.
With this feature you can connect the xtures to one another
using the IEC input and output sockets. The maximum that can
be connected is 16 xtures @ 120V and 29 xtures @ 240V. After
the maximum connected fixtures you will need to use a new
power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES
TO THE UB 6H AS THE POWER CONSUMPTION OF OTHER
LIGHTING FIXTURES WILL VARY!
UB 6H Multiple Unit Power Linking
UB 6H Operating Instructions