Specifications
Power Supply: The ADJ Mega Par Prole Plus contains a automatic 
voltage switch, which will auto sense the voltage when it is plugged 
into the power source. With this switch there is no need to worry about 
the correct power voltage, this unit can be plugged in anywhere. 
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 
DMX Linking: DMX is a language allowing all makes and models of 
dierent manufactures to be linked together and operate from a single 
controller,  as  long  as  all  xtures and the  controller are DMX compli-
ant.  To ensure proper DMX data transmission, when using several 
DMX fixtures try to use the shortest cable path possible. The order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): 
The Mega Par Prole Plus can be controlled via DMX-512 protocol. The 
Mega  Par  Prole Plus  has  5  DMX  modes,  please  see  pages  9-10  for 
the dierent modes. The DMX address is set on the back panel of the 
Mega  Par  Prole  Plus.  Your  unit  and  your  DMX 
controller require a standard 3-pin XLR connec-
tor for data input and data output (Figure 1). We 
recommend Accu-Cable DMX cables. If you are 
making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all pro lighting stores). Your 
cables should be made with a male and female 
XLR connector on either end of the cable. Also 
remember that DMX cable must be daisy chained 
and cannot be split.
 Mega Par Profile Plus DMX Set Up
ADJ Products, LLC - www.adj.com - Mega Par Prole Plus User Manual Page 5
Figure 1
ADJ Products, LLC - www.adj.com - Mega Par Prole Plus User Manual Page 26
 Mega Par Profile Plus Trouble Shooting
Listed below are a few common problems the user may encounter, 
with solutions.
Unit not responding to DMX:
1.  Check that the DMX cables are connected properly and are   
  wired correctly (pin 3 is “hot”; on some other DMX devices   
  pin 2 may be ‘hot’). Also, check that all cables are connected  
  to the right connectors; it does matter which way the inputs   
  and outputs are connected.
Unit does not respond to sound:
1.  Quiet or high pitched sounds will not activate the unit.
2.  Make sure that Sound Active mode is activated.
 Mega Par Profile Plus Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light 
output. 
1. Use normal glass cleaner and a soft cloth to wipe down the 
  outside casing.
2. Clean the external optics with glass cleaner and a soft cloth 
  every 20 days.
3.  Always be sure to dry all parts completely before plugging 
  the unit back in.
Cleaning frequency depends on the environment in which the fixture 
operates (i.e. smoke, fog residue, dust, dew). 
Disconnect the unit from its power source. Remove the power cord 
from the unit. Once the cord has been removed, you will find that the 
fuse holder is located inside the power socket. Insert a flat-head screw 
driver into the power socket and gently pry out the fuse holder. Remove 
the bad fuse and replace with a new one. The fuse holder also has a 
holder for a spare fuse.
 Mega Par Profile Plus Fuse Replacement
With  this  feature  you  can  connect  the  xtures  to  one  another 
using the IEC input and output sockets. The quantity that can be 
connected is 33 xtures maximum. After 33 xtures you will need 
to use  a  new power outlet.  They  must be the  same  xtures. DO 
NOT mix xtures.
 Mega Par Profile Plus Power Cord Daisy Chain