User manual
ADJ Products, LLC - www.adj.com - Encore Burst 100 IP User Manual Page 17
 Encore Burst 100 IP Operating Instructions
Max Resettable - With this function you are able to check the current highest temperature 
the xture has reached. This temperature may not be the same as the temperature displayed under 
“CURRENT” or “MAX NOT RESETTABLE”. This temperature CAN be reset.
NOTE: The displayed temperature represents the highest temperature the xture has reached 
since the last reset. 
1. Press either the MENU, UP, or DOWN buttons until “Information” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Fixture Temps” is displayed and press ENTER.
3. Press the UP or DOWN buttons until “Max Resettable” is displayed and press ENTER.
4. The xtues hightest temperature will now be displayed. Press the UP or DOWN buttons to switch   
  between farenheit and celsius. Press the MENU button to exit.
Max Not Resettable - With this function you are able to check the highest temperature the 
xture has reached. This temperature can NOT be reset, and could continue rise. 
1. Press either the MENU, UP, or DOWN buttons until “Information” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Fixture Temps” is displayed and press ENTER.
3. Press the UP or DOWN buttons until “Max Not Resettable” is displayed and press ENTER.
4. The xtues hightest temperature will now be displayed. Press the UP or DOWN buttons to switch   
  between farenheit and celsius. Press the MENU button to exit.
Rst Temp History - With this function you can reset the MAX RESETTABLE temperature.
NOTE: When the temperature is reset, the temperature will revert to the CURRENT temperature. 
1. Press either the MENU, UP, or DOWN buttons until “Information” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “Fixture Temps” is displayed and press ENTER.
3. Press the UP or DOWN buttons until “Rst Temp History” is displayed and press ENTER.
4. Use the UP or DOWN buttons to set the pass code to “50” and press ENTER. The MAX RESETTABLE  
  temperature will now reset to the CURRENT xture temperature.
DMX Values - With this function you can check the DMX values of each DMX channel that 
is currently in use.
1. Press the MENU button until “Information” is displayed and press ENTER.
2. Press the UP or DOWN buttons until “DMX Values” is displayed and press ENTER.
3. Use the UP or DOWN buttons to nd the DMX channel you would like check and press ENTER.   
  The current DMX value of that channel will now be displayed. Press the MENU button to exit. 
Software Version - Use this function to display the Software version of the unit.
1. Press the MENU button until “Information” is displayed, press ENTER.
2. Press the UP or DOWN buttons until “Software Version” is displayed and press ENTER.
3. The current software version will now be displayed.