Manual
CONTROLS & FUNCTIONS
1.   SCANNER BUTTONS - Used to Select any or all of 12 fixtures This  
            is what selects which DMX channels go to    
                   the fixtures. 
            Scanner 1 controls Channel 1 to 16
            Scanner 2 controls Channel 17 to 32
  See addressing of fixtures on page 7 for more information     
2.  SCENE BUTTONS - Used to store Scenes in program mode or 
                         playback your scenes in playback mode
3.  LCD DISPLAY - Displays values and settings depending on the 
                   chosen function.
4.  BANK BUTTONS (   OR    )-   Selects which Bank you want to use.
                                    (there are 30 selectable banks total.)
5.  
CHASE - Used to select chases (1-6).
6.  PROGRAM - Used to activate program mode Display blinks when    
              activated.
7.   MIDI / REC - Used to control MIDI operation or to Record each   
        step for Scene and Chases.
8.  
AUTO/DEL- Select AUTO speed in chase mode or  Deletes 
               Scenes and or chases .
9.  MUSIC / BANK COPY- Used to trigger sound activation in Chase  
                             mode or to copy a bank of scenes from one to              
                          another in Program Mode
10.  BLACKOUT - Disables or enables all channel outputs 
11.  TAP SYNC / DISPLAY -  In Auto Chase mode used to change   
                            rate of chase also to change LCD Display in              
                              Manual Chase.
12.  FADE TIME SLIDER - Used to adjust the FADE TIME.  Fade Time is        
                           the amount of time it takes the DMX Operator 
                           to completely change from one scene to another.  
For example; if the fade time slider is set to 0 (zero) a scene change will 
be instant. If the slider is set to ‘30s’ it will take the  DMX Operator 30 sec
-
onds to complete the change from one scene to the next.
13.  SPEED SLIDER - Used to adjust the rate of chase speed in Auto 
                       Mode.
14.  PAGE SELECT - Used to select faders between PAGE A (1-8) and 
                      PAGE B (9-16) of each Scanner Button 
15.  FADERS (1-8) - Used to adjust the intensity from 0% to 100% or DMX 
                     output level from 0 to 255 of each channel 
REAR CONTROLS
16.  MIDI IN-  Receives MIDI data.
17.  DMX POLARITY SELECT-  Changes the polarity setting of the DMX 
                               output.
18.  DMX OUT-  Used to send DMX signal to fixtures or Packs.
19.  DC INPUT-  Accepts a DC 9~12V,  300 mA minimum, power 
               supply.
+9V-+12V 300mA Min.
DC INPUT
+-
1:GND
2:DATA -
3:DATA +
1:GND
2:DATA +
3:DATA -
DMX OUT
DMX POLARITY
SELECT
MIDI IN
16
17 18 19
DMX512 ADDRESSING
WHEN ADDRESSING YOUR FIXTURES FOLLOW THE STARTING 
ADDRESS IN THIS BOOK NOT THE ADDRESSING FOUND IN YOUR 
FIXTURE MANUAL
DMX 512 is a type of protocol that sends out up to 512 multiplex 
channels at once down a common cable. Each channels has a value 
from 0 to 255. You set the address for each receiver(fixture) by using 
Dip switches or some type of digital readout
Each Dip switch has an ADDRESS based on binary code.
Dip switch  #1  #2 #3 #4 #5  #6 #7  #8   #9
Value      1   2  4  8 16  32 64  128 256
  YOU SELECT THE ADDRESS WANTED BY ADDING THE TOTAL OF 
DIP SWITCHES ON.
Dip switch #10 is not used with DMX but normally to select some 
Function ie: Master / Slave, Sound Activation or to receive DMX 
Control.