User manual
ADJ Products, LLC - www.adj.com - WiFly EXR QA5 IP User Manual Page 18
WiFly EXR QA5 IP Master-Slave Configuration
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave setup. In a Master-Slave set up one unit will act as the control-
ling unit and the others will react to the controlling units built-in pro-
grams. Any unit can act as a Master or as a Slave however, only one
unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the
unit. Use standard XLR data cables to link your units together.
Remember that the Male XLR connector is the input and the
Female XLR connector is the ouput. The first unit in the chain
(master) will use the female XLR connector only. The last unit in
the chain will use the male XLR connector only.
2. Set the “Master” unit to your desired mode of operation.
3. On the “Slave” units press the MODE button until “Slave Mode” is
displayed. The unit is now set as the “Slave” unit. Each slave unit
must be set to the same setting.
4. Connect the rst “Slave” unit to the “Master”, and the “Slave” unit
should now start to follow the “Master”.
ADJ Products, LLC - www.adj.com - WiFly EXR QA5 IP User Manual Page 17
cally go into the last DMX set up.
Dimmer Curve Setting:
This is used to set the dimming curve used with DMX mode. See
page 29 for the different dimming curves.
1. Plug the fixture in and press the MODE button until “DMX MODE
ADDR:XXX” is displayed.
2. Press the SET UP button until “DELAY:X” is displayed. “X” repre-
sents the displayed dimmer curve (0-4).
• 0 - Standard
• 1 - Stage
• 2 - TV
• 3 - Architectural
• 4 - Theatre
3. Press the UP or DOWN buttons to scroll through and select your
desired dimming curve
WiFly EXR QA5 IP Operating Instructions