Instruction manual

80
10 GB Communication
Version
1.0
3
& Control Card Instruction Manual
6 Electrical Characteristics
Recommended operating conditions:
Parameter
Min
Typ
Max
Units
VCC (power supply)
3.2
6
3.3
3.4
1
V
Input current
3000
mA
Operating temperature
+5
+70