Instruction manual

53
10 GB Communication
Version
1.0
3
& Control Card Instruction Manual
SETSAMPLECOUNT instruction
Byte
7
6
5
4
3
2
1
0
1
-
2
Opcode
0x0
114
3
-
4
Length
0x0006
5
-
10
Sample Count (MSB..LSB)
Description:
Set the Sample Count. (Use the SAVESETTINGS instruction to save
changes to the EEPROM.)
SETTRIGGER instruction
Byte
7
6
5
4
3
2
1
0
1
-
2
Opcode
0x0
115
3
-
4
Length
0x0005
5
0
DT
0
0
0
IT
ETF
ETR
6
-
9
Trigger Delay (MSB..LSB)
Description:
Set the Trigger Control and the Trigger Delay (in us) values. The
SETTRIGGER instruction clears the Trigger Status. (Use the SAVESETTINGS
instruction to save changes to the EEPROM.)
ETR: 0/1 – External trigger rising slope disabled/enabled
ETF: 0/1 – External trigger falling slope disabled/enabled
IT: 0/1 – Internal trigger disabled/enabled
DT: Disable trigger event if streams are disabled (1)
CLEARTRIGGERSTATUS instruction
Byte
7
6
5
4
3
2
1
0
1
-
2
Opcode
0x0
116
3
-
4
Length
0x0000
Description:
Clear the Trigger Status.