Instruction manual

9
10 GB Communication
Version
1.0
3
& Control Card Instruction Manual
4.2 Device Management
Building the network and connecting the devices is made using the
standard elements used in computer networks, no special elements or cables
are required. For connecting a device UTP (Unshielded Twisted Pair) cables of
at least category 5 have to be used. The connections are made with RJ45 8-
pin telephony connectors (Connector F) or XFP modules (Connector G).
The management port complies with the 10Base-T and 100Base-TX
IEEE 802.3 standards (UTP cable only). The Stream port contains a Marvell
88X2012 integrated 10 GB Ethernet transceiver that complies with the IEEE
802.3ae standard. The Marvell PHY provides all the necessary physical layer
functions to over optical cable. The 10 GB C&C Card operates in full-duplex
mode.
Using the management port the card can easily be programmed via
UDP/IP or HTTP (TCP/IP). The device supports Digital Data Transmission over
IP version 3 (DDToIPv3) protocol.
The 10 GB C&C Card supports several protocols that do not belong
closely to the device management:
ARP query and request (see RFC 826.)
ICMP PING (see RFC 792)
DHCP
DDToIPv1 compatibility: The device answers to SENDACK instruction.
DDToIPv2 compatibility: The device answers to SENDACK (General
ACK Type) instruction.