Specifications

5-98 Menus and Commands
600561-A
Drives Dialog
When
Drives
is selected, the Drives Dialog is displayed. See
Figure 5-110. This options allows modification of the drive
SCSI ID for the Model 4001S, Model 7001S, Model 8001S,
AIT3102, AIT5002, AIT5102, and NCTP drives.
Figure 5-110 Drives Dialog
Step 1 Press the button to select the current
parameter value and move to the next parameter.
or
Press the button or the button to toggle
between the parameter values in the following list.
Parameters Values
Override Enabled allows the operator to
enable the setting of SCSI ID
for supported drives
Disabled prevents the library
from setting the SCSI ID for
supported drives
Set Drive ID Y to view and set the drive
SCSI ID
N to not change the drive SCSI
ID
Accept Y to accept changes
N to reject changes
Press the button to confirm the changes.
If Enabled is selected or was previously selected for the
Drive ID Override parameter and Y is selected for the Set
Drive Id and the Accept parameters, the SCSI ID Dialog
appears. Refer to Figure 5-111 on page 5-99.
Drive ID Override:
Enabled <
Set Drive ID: N
Accept: N