Specifications
5-56 Menus and Commands
600561-A
Insert Clean Tape Dialog
When
Insert Clean Tape
is selected, the Insert Clean
Tape Dialog is displayed. See Figure 5-66. This option moves
selected cleaning cartridges from the Insert/Eject station to
the designated empty storage cells.
Figure 5-66 Insert Clean Tape Dialog
Step 1 Press the button to select the current
parameter default value and move to the next
parameter.
— or —
Press the button or the button to toggle
the Element parameter values.
Parameters Value
Coord The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell)
The second field indicates the
module number which can be
modified if expansion
modules are present (1 .. 4)
The third field indicates the
storage cell section (1 .. 4),
drive bay (1 .. 2), or IE station
number
The fourth field indicates the
column of the section (A .. E),
drive port (A .. B) or IE station
column
The fifth field indicates the
row of the column. (01 .. 12 for
half inch and DLT
coordinates)
(01 .. 18 for 8mm coordinates)
Enter SOURCE
Coord: I 01< 1 A 01
OR Element: 01182
Accept: N