Specifications
Due to our policy of continuous improvement we reserve
the right of modifying specifications and appearance.
Code
Class
SLP-880V/3
2
Special Surge Protection for Invertors (e.g. Wind Turbines)
No. of
Poles
3
Up
<3.2kV
Uc
880V
Backup
MCB
160A
Network
TN-S/TN-C/TT
Max.
Discharge
8/20µS
40kA
DIN
Width
3
Code
Nominal
Discharge
8/20µS
No of
Poles
Photovoltaic System Protection
Max
Discharge
8/20µS
Up
Uc
Uoc stc DIN Width
Uoc stc refers to the maximum voltage of the photovoltaic panel
SLP-170PHV/2
SLP-600 V/U
SLP-700PHV/3
SLP-1000PHV/3
2
2
3
3
15kA
20kA
20kA
20kA
40kA
40kA
40kA
40kA
0.8kV
4.0kV
2.4kV
3.6kV
170VDC
600VDC
350VDC
500VDC
170VDC
720VDC
700VDC
1000VDC
2
2
3
3
21
A range of fuse links in a 10 x 38mm packaging specifically designed for protection and isolation of photovoltiac strings.
The fuse links are capable of interrupting low overcurrents associated with faulted PV string arrays.
General Characteristics
• Rated Voltage: 1000Vdc • Rated breaking capacity: 33kA (VDC)
• Time constant (L/R): under 1ms • Minimum interrupting rating 1.3 x In
Characteristics
• 1000VDC - DC-20B
• Mounting 35mm DIN rail
• Hight temperature resistant plastics
• Elevated insulation characteristics
211PV
32A
10 x 38 1 pole 1
Code
Thermal
Rating
Fuse Size
Poles
DIN
Modules
According To
• IEC 60947-1
• IEC 60947-3
DC FUSEHOLDERS
10x38 Fuse Holders for DC Applications
Accessories
Code Description
21KE
Multipole assembly kits
For multipole fuse holders use multipole assembly kits - 21KE
SOL
Current Rating
Power Loss
0.8In In
6A
8A
10A
12A
15A
20A
1.1W
1.2W
1.3W
1.5W
1.7W
2.1W
1.8W
2.1W
2.3W
2.7W
2.9W
3.6W
30F6PV
30F8PV
30F10PV
30F12PV
30F15PV
30F20PV
Code
LIGHTING & SURGE PROTECTION
PST25/31: Surge protection devices Class II are developed to protect PV Photovoltiac networks against atmospheric lightning. These
units must be installed in parallel on the DC networks to provide common and differential mode protection. The design is based on
high energy MOVs equipped with specific thermal disconnectors and related failure indicators.
PST41: Surge protector devices Class I are recommended for both ends of the DC power supply line. Due to their extraodinarily
high discharge capacity, they are recommended for use on installations with elevated risk of direct lightning strikes. The protection is
based on high energy MOVs and specific thermal disconnectors achieving a superior protection level and a lack of follow-up current.
Code
Class
In
80/20
Iimp
10/350
No of
Poles
PST25PV
PST31PV
PST41PV
2
2
1+2
2
3
2
20kA
20kA
40kA
-
-
12.5kA
Imax
8/20
40kA
40kA
-
Up
2.2kV
3.0kV
1.9kV
Uc
550VDC
1000VDC
1000VDC
DIN Width Auxilliary
2
3
3
N
N
Y
Photovoltaic System Protection
GPV FUSE PROTECTION
Temperature Derating Curves
GPV FUSE PROTECTION