Specifications

Due to our policy of continuous improvement we reserve
the right of modifying specifications and appearance.
Features
• Extra start-up power • Low Battery Protection • Self diagnostic function • LED fault diagnosis • Remote on/off switch • Input/output protection
Code
Code 24V
Code 48V
Com Card
Datamanager Card
Datalogger Web
FRONIUS-DW
12VDC
1.43W
RS422 / Ethernet / USB
Relay: 6A@30VDC / 6A@42VAC
190 x 114 x 53mm
230VAC (+10%/ -15%)
60mA
RS422 (RJ45) x2 (In/Out)
140 x 100 x 28mm
Power Control Box
230VAC (+10%/ -15%)
2.2W
RS422 / Ethernet / WLAN, 6 Digital
Inpus, 4 Digital Inputs/Outputs
(Ripple Control Interface)
132 x 103 x 22mm
12VDC
1.3W
RS422 (RJ45) x2 (In/Out)
2,3 & 4-Stage ripple-control
signal receivers
197 x 110 x 57mm
Co
m
Ca
rd
Fronius PT1000Fronius ISFronius SBox Fronius WS
Irradiation SensorSensor Box
Wind Speed Sensor
Module Temperature
Phoenix range of inverters are suitable for the widest range of applications. The design criteria have been to produced a true sine wave inverter with optimized
efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and
capable of supplying power, problem-free to any load
. A unique feature is very high start up power.
Max. con Power (25°C)
Peak power (W)
Input DC range
Output voltage
No. Load Consumption
Battery connection
Dimensions
GX-12/180 GX-12/350 GX-12/800 GX-12/1200
GX-24/180
180VA/175W
350
72x132x200
800VA/700W
1600
108x165x305
1200VA/1000W
2400
108x165x305
230VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Screw terminals
GX-24/350 GX-24/800 GX-24/1200
GX-48/350 GX-48/800 GX-24/1200
12VDC
1.3W
-
197 x 110 x 57mm
Measurement of addition-
al data by connecting
various sensors.
-
-
Mono Crystalline Si-Sensor
± 70mV@100W/m
2
110 x 40 x 40mm
This sensor is for
measuring the irradiated
energy.
-
-
PT1000
-20°C to +150°C
50 x 100mm
Sensor on adhesive film
for module temperature
measurement.
-
-
Cup Anemometer
Pulse Output
18.79Hz = 1m/s
85 x 93 x 115mm
The sensor measures the
exact speed of the wind
.
Phoenix Inverters
Supply Voltage
Power usage
Interfaces
Dimensions
Information
Code
Supply Voltage
Power usage
Interfaces
Dimensions
Information
Code
PURE SINE WAVE INVERTERS
Code 12V
Datalogging for up to 4096 days.
This enables you to get system
information for up to 100 invert-
ers in real-time. Inverters must
be equipped with com card.
Datalogging for up to 4096 days.
Enables inverters to be connected
directly to the internet for remote
monitoring & control. Integrated
web server. Only 1 inverter in 100
needs to be fitted with this card.
Other inverters must be equipped
with com card.
Com card is a network card that
each inverter requires for data
communication.
Remote-controlled power
reduction of PV systems
>100kW. Inverters must be
equipped with com card and
one datalogger is required per
system.
c/w 3m Cable
Ambient Temperature
-
-
PT1000
-40°C to +180°C
Ø 6 x 50mm
Sensor for measuring
indoor & outdoor
temperature.
c/w 3m Cablec/w 3m Cable
D
a
t
amana
ge
r
C
a
rd
FRONIUS-DM FRONIUS-CC FRONIUS-PCBOX
FRONIUS-SBOX FRONIUS-IS FRONIUS-MT FRONIUS-WS FRONIUS-AT
-
350VA/300W
700
72x155x237
10.5 - 15.5VDC / 21 - 31VDC / 42 - 62VDC 9.2 - 17.3VDC / 18.4 - 34VDC / 36.8 - 68VDC
2.6W / 3.8W 3.1W / 5W / 6W 6W / 5W / 4W 6W / 5W / 6W
17
SOL