Specifications

Due to our policy of continuous improvement we reserve
the right of modifying specifications and appearance.
16
Output Data
AC nominal output (P
ac, r
)
Max. output power
Max. output current (I
ac max
)
Grid connection (U
ac, r
)
Min. output voltage (U
ac min
)
Max. output voltage (U
ac max
)
Frequency (f
r
)
Frequency range (f
min
- f
max
)
Distortion factor
Power factor (cosØ
ac, r
)
55V-3 60V-3 80V-3 100V-3 120V-3 150V-3
5.000W
5.000VA
7.3A
6.000W
6.000VA
8.7A
7.000W
7.000VA
10.2A
8.000W
8.000VA
11.6A
10.000W
10.000VA
14.5A
12.000W
12.000VA
17.4A
3-NPE 400V/ 230V
180V
270V
50Hz/ 60Hz
46 - 65Hz
<3%
0.75 - 1ind./ cap
General Data
Dimensions (height x width x depth)
Weight
Degree of protection
Protection class
Overvoltage category (DC/ AC)
Night time consumption
Inverter type
Cooling
Installation
Ambient temperature range
Permitted humidity
DC connection technology
AC connection technology
1.263 x 434 x 250mm
49.2kg
IP54
1
2/ 3
ca. 1W
High Frequency Transformer
Regulated air cooling
Indoor & outdoor installation
from 20°C to +55°C
0% to 95%
Screw terminal connection 1.5mm
2
- 16mm
2
Screw terminal connection 2.5mm
2
- 35mm
2
55V-3 60V-3 80V-3 100V-3 120V-3 150V-3
Input Data
55V-3 60V-3 80V-3 100V-3 120V-3 150V-3
5.250W
22.8A
34.2A
6.300W
27.5A
41.3A
7.360W
32.0A
48.0A
8.430W
36.7A
55.1A
10.590W
46.2A
69.3A
12.770W
55.6A
83.4A
230V
260V
370V
600V
230 - 500V
6
DC maximum power at cos Ø=1
Max. input current (I
dc
max)
Max array short circuit current
Min. input voltage (U
dc
min)
Feed-in start voltage (U
dc
start)
Nominal input voltage (U
dc
max)
Max input voltage (U
dc,1
)
MPP voltage range (U
mpp
min
- U
mpp
max
)
Number of DC inputs
The Fronius IG Plus generation of inverters represents an evolution of the proven Fronius IG product family. Power categories from 2.6 to 12kW promise suitability
for every possible system size. With a maximum effeciency of 95.9%, the Fronius IG Plus range achieves one of the highest values for transformer inverters.
Code
FIGP55V-3 FIGP60V-3 FIGP80V-3 FIGP100V-3 FIGP120V-3 FIGP150V-3
THREE PHASE GRID TIE INVERTERS
SOL
Fronius inverters always achieve maximum yield, even when in the partial-load range.
This is all down to the unique Fronius Master Inverter X-Change system (MIX
TM
).
The "master" is allocated alternately, taking into account the operating hours worked.
Fronius transformer inverters use a high-frequency (HF) transformer. The automatic
transformer switchover facility produces three efficiency peaks. The result: a constant
level of efficiency across the entire input voltage range, resulting in higher yields.
kfd
With the Fronius Datamanager, we offer a WLAN interface in the
inverter itself. The inverter is connected to the internet without
additional cabling and grants you the perfect overview of how the PV
system is operating. (Optional)
kfd
Fronius inverters are ready for the Smart Grid of tommorrow.
A series of smart functions, known as Advanced Grid Features,
are built into the devices.
kfd
t
rans
f
ormer
i
nver
t
ers
.
2
0V
-3
FI
GP
15
0V