Specifications
Due to our policy of continuous improvement we reserve
the right of modifying specifications and appearance.
13
Code
Rated Input DC Power
Absolute max input voltage
MPPT Operating range
Max input current
Max Output current
Operating Output Voltage
Total max string voltage 1ph/ 3ph
Min number Optimizers
Max number Optimizers
250
47
5-47
10
300
55
5-55
10
400
75
5-75
12.5
400
130
15-130
7
W
VDC
VDC
A
A
VDC
VDC
-
-
15
5-60
500/ 950
8 (1Ph system)/ 16 (3Ph system)
Module power dependant: Maximum 25 (1Ph system)/ 50 (3Ph system)
RATINGOPA250-RV OPA300-LV OPA400-MV OPA400-EV
Code
Description
Kit consists of
2- Module branch cable
20 male & 20 female units in each pack
3- Module branch cable
10 male & 10 female units in each pack
4- Module branch cable
10 male & 10 female units in each pack
SE-CBY-2MM SE-CBY-3MM
SE-CBY-4MM
Ideal solution for low power modules
• Allows to connect 2-4 modules in parallel to a single power optimizer • Utilize power optimizers to their full power rating
• Double insulated PV wire • Multi-contact MC4 connectors
• Max current 30A @ 1000VDC
A superior approach to maximizing the throughput of photovoltaic systems
• Up to 25% more energy - module-level MPPT eliminates power loss due to module mismatch
• Superior effeciency- peak (99.5%), weighted (98.9%)
• Next gereration maintenance with module-level monitoring and smart alerts
• Automatic DC safety
• Maximum roof utilization
• Independant optimization technology (IndOPTM)
The most cost effective solution for residential, commercial and large field installations
Only for use with Solar Edge Inverters
SE-CBY-2MM
SE-CBY-4MM
SE-CBY-3MM
Benefit from module-level monitoring and automatic safety with non-SolarEdge inverters.
• Interface between SolarEdge power optimizers and non-SolarEdge inverters
• Module safety voltage for installer and firefighter safety
• Mobile and web-based module level performance monitoring
• Communication via RS232, RS485 or Ethernet
•
IP65 for outdoor installation
The SolarEdge safety and monitoring interface collects module performance data measured by each
power optimizer, as well as inverter data*, and interfaces with the SolarEdge server to allow module-level
and system-wide monitoring. (For communication options please see page 14)
Code
SMI-35-3C-01
Additional Features
DC Input
1000VDC
35A
3 x MC4 Compatible
85 - 264VAC
47 - 62Hz
300mA
Supported voltage
AC Frequency
Max input current
Display LCD & LED
Remote monitoring Yes
Module Safety DC Voltage
Yes
On-site Master shutdown
Yes
Lighting Protection
Yes
Read inverter data
Yes
DC Current Sense Yes
Max input voltage
Total max current
Input type
AC Input
POWER OPTIMIZER
BRANCH-CABLE FOR POWER OPTIMIZER INPUT
SAFETY & MONITORING INTERFACE
SOL
13