Storage conditions:
Store in a well-ventilated place. Keep dry. Keep container closed when not in use.
Storage area:
Store in a well-ventilated place.
Special rules on packaging:
Keep only in original container.
BENZOTRIAZOLE (95-14-7)
Not applicable
Triethanolamine (102-71-6)
ACGIH
ACGIH TWA (mg/m³)
5 mg/m³
ACGIH
Remark (ACGIH)
Eye & skin irr
Appropriate engineering controls:
Ensure good ventilation of the work station.
Personal protective equipment: Gloves. Safety glasses.
Materials for protective clothing: Wear suitable working clothes.
Hand protection: Protective gloves.
Eye protection: Eye protection should only be necessary where liquid could be splashed or
sprayed.
Skin and body protection: Wear suitable protective clothing.
Respiratory protection: No specific recommendation made, but respiratory protection may still be
required under exceptional circumstances when excessive air contamination
exists.
Environmental exposure controls: Avoid release to the environment.
Physical state:
Liquid
Color:
Pale yellow to yellow
Odor:
Mild
Odor threshold:
No data available
pH:
7.5 – 8.5
Melting point: Not applicable
Freezing point: No data available
Boiling point: No data available
Flash point: No data available
Relative evaporation rate
(butylacetate=1): No data available
Flammability (solid, gas): Not applicable
7.2. Conditions for safe storage, including any incompatibilities
Section
8:
Exposure
controls/personal
protection
8.1. Control parameters
8.2. Exposure controls
Section
9:
Physical
and
chemical
properties
9.1. Information on basic physical and chemical properties