Figure 3-5. Front Panel Schematic
Emergency Stop Circuits
The SmartController provides connections for Emergency Stop (E-Stop) circuits on the
XUSR and XFP connectors. This gives the SmartController system the ability to duplicate
E-Stop functionality from a remote location using voltage-free contacts. See Figure 3-4 on
page 53.
The XUSR connector provides external two-channel E-Stop input on pins 1, 14 and 2, 15.
The XFP connector provides two-channel E-Stop input on pins 1 to 9 and 2 to 10.
NOTE: These pins must be shorted if not used. Both channels must open
independently if used. Although an Emergency Stop will occur, the
SmartController will flag an error state if one channel is jumpered closed
and the other channel is opened. It will also flag an error state if the
channels are shorted together.