Specifications
Chapter 1 - Introduction
24 Adept SmartController User’s Guide, Rev. H
Operational Change in SmartModule Systems
When a CAT-3 SmartController is used in an Adept system that includes a PDU-2 or
PDU-3, there is a minor change in operation compared to the original SmartController.
The sequence would be:
1. In a SmartModule system with a CAT-3 SmartController, while operating in
Manual Mode, power is turned off by releasing the Enable switch on the pendant.
2. To re-enable power, the user must press and hold the Enable switch.
3. Next the user must press the COMP/PWR button on the pendant.
4. Then the user must press the High Power button on the Front Panel to turn on
High Power to the robot. The LCD display on the pendant will instruct the user to
press the button. The button will be blinking, and must be pressed within 10
seconds. (Ten seconds is the default timeout for the High Power button to be
pressed. This timeout can be changed using the CONFIG_C utility.)
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com