Specifications
Standards Compliance
Adept SmartController User’s Guide, Rev. H 21
Program Security
Programs and data stored in memory can be changed by trained personnel using the V
+
commands and instructions documented in the V
+
manuals. To prevent unauthorized
alteration of programs, you should restrict access to the keyboard. This can be done by
placing the keyboard in a locked cabinet. Alternatively, the V
+
ATTACH and FSET
instructions can be used in your programs to restrict access to the V
+
command prompt.
Inappropriate Uses of the Adept SmartController
The Adept SmartController is intended for use as a component subassembly of a complete
industrial automation system. The SmartController subassembly must be installed inside
a suitable enclosure. Installation and usage must comply with all safety instructions and
warnings in this manual. Installation and usage must also comply with all applicable local
or national statutory requirements and safety standards. The SmartController
subassembly is not intended for use in any of the following situations:
• In hazardous (explosive) atmospheres
• In mobile, portable, marine, or aircraft systems
• In life-support systems
• In residential installations
• In situations where the SmartController may come into contact with liquids.
• In situations where the SmartController will be subject to extremes of heat or
humidity. See specifications for allowable temperature and humidity ranges.
1.6 Standards Compliance
The Adept SmartController is intended for use with other equipment and is considered a
subassembly rather than a complete piece of equipment on its own.
If the Adept SmartController is used with equipment other than the equipment with
which it was evaluated for standards compliance, you might invalidate its compliance
with these standards.
The SmartController meets the requirements of these standards:
Table 1-2. Standards Met by Controller
Standard
UL 1740
ANSI/RIA R15.06
NFPA 79
CSA/CAN Z434
EN 954