Specifications
Configuring an sDIO
Adept SmartController User’s Guide, Rev. H 99
5. Type N at the following prompt:
Attached controller 0. Change this value?
Press ENTER to continue.
6. Type Y at the following prompt:
Digital input block: 16 Change this value?
Press ENTER to continue.
7. Enter a new value for the input block at the following prompt:
Enter new value:
Press ENTER to continue.
8. Type Y at the following prompt:
Digital output block: 16 Change this value?
Press ENTER to continue.
9. Enter a new value for the output block number at the following prompt:
Enter new value:
Press ENTER to continue.
10. Type Y at the final prompt:
Do you want to save these changes?
Press ENTER to continue.
After selecting block numbers, you must assign groups of signal numbers to each block.
NOTE: You must select a unique block number for the Inputs and
Outputs of each sDIO in your system. Repeat the procedure above for
each sDIO.
Assigning I/O Signal Numbers
The I/O signal number ranges are valid for the sDIO:
• Inputs 1033 to 1512
• Outputs 0033 to 0512
You will need to perform the following steps to assign I/O signals to specific blocks if you
choose a block other than 16.
1. Load and Execute the CONFIG_C.V2 utility.